Owon XSA1032-TG - spectrum analyzer from 9 kHz up to 3.2GHz

XSA1000TG Series Spectrum Analyzer

  • Frequency Range from 9 kHz up to 7.5 GHz
    • 160dBm Displayed Average Noise Level
  • Phase Noise -98dBc/Hz @1Gz and offset at 10KHz
  • Total Amplitude Accuracy <1.5dB
  • 10Hz Minimum Resolution Bandwidth (RBW)
  • EMI Pre-compliance Test Kit, optional EMC test software
  • Standard Pass/Fail on-site test alert ability
  • Up to 7.5 GHz Tracking Generator Kit
  • 10.4 inches display

Specifications

Model

XSA1032TG)

Frequency

Range

9kHz-3.2 GHz

Resolution

1Hz

Frequency span

Range

0 Hz,100 Hz to maximum frequency of device

Accuracy

± span /(swept points -1)

Internal reference

Reference frequency

10.000000 MHz

Reference frequency accuracy

±[(days from last calibrate × freq aging rate)+ temperature stability + initial accuracy ]

Temperature stability

<2.5ppm (15℃ to 35℃)

Aging rate

<1ppm/year

Readout

Marker frequency resolution

span/(the number of sweep points -1)

Uncertainty

±(freq indication × freq reference uncertainty +1%× span +10%× resolution bandwidth + Marker Frequency Resolution)

Frequency counter

Resolution

1 Hz,10 Hz,100 Hz,1 kHz

Accuracy

±(marker freq × freq reference uncertainty + counter resolution)

Bandwidth

Resolution bandwidth (-3 dB)

10Hz to 500kHz(in 1 to 10 sequence), 1MHz,3MHz

Resolution filter shape factor

<5:1 nominal(Digital implement, similar to Gauss Pattern)

Accuracy

<5% nominal

Video bandwidth (-3 dB)

10Hz to 3MHz

Amplitude Specification

Amplitude and electric level

Amplitude measurement range

DANL to +20 dBm, close the preamplifier

Reference electric level

-80 dBm to +30 dBm,0.01dBm steps

Preamplifier

20 dB,nominal

Input attenuator range

0~50 dB,1 dB steps

Max input DC voltage

50 VDC

Max continuous power

+30dBm,average continuous power

Displayed average noise levelDANLInput attenuation 0 dB,1Hz resolution bandwidth

Preamp off

1 MHz~10 MHz -140dBm(nominated)

10 MHz~1GHz -140dBm(nominated)

XSA1015TG:1GHz~1.5 GHz -138 dBm( nominated )
XSA1032TG:1GHz~3.2GHz -138 dBm( nominated )
XSA1036TG:1GHz~3.6 GHz -138 dBm( nominated )
XSA1075TG:1GHz~3.6GHz -138dBm( nominated );4GHz~5GHz,-133dBm( nominated )
5GHz~6GHz,-128dBm( nominated );6GHz~7GHz-123dBm( nominated );
7GHz~7.5GHz,-118dBm( nominated )

Preamp on

1 MHz~10 MHz -160dBm(nominated)

10 MHz~1GHz -160dBm(nominated)

XSA1015TG: 1GHz~1.5 GHz -158 dBm( nominated )
XSA1032TG: 1GHz~3.2 GHz -158 dBm( nominated )
XSA1036TG: 1GHz~3.6 GHz -158 dBm( nominated )
XSA1075TG: 1GHz~4GHz -158dBm( nominated );4GHz~5GHz -153dBm( nominated )
5GHz~6GHz -148dBm( nominated );6GHz~7GHz -143dBm( nominated )
7GHz~7.5GHz -138dBm( nominated )

Phase noise

20 ℃ ~30 ℃,fc=1 GHz

Phase noise

<-82 dBc/Hz @10 kHz offset

<-100 dBc/Hz @100 kHz offset

<-110 dBc/Hz @1 MHz offset

Level display range

Log scale coordinate

1dB ~255dB

Linear scale coordinate

0 to reference level

level unit

dBm, dBuW, dBpW, dBmV, dBuV, W,V

Points

201~1001

Number of traces

5

Detectors

Positive-peak, negative-peak, sample, normal, RMS

Trace functions

Clear write, Max Hold, Min Hold, View, Blank, Average

Frequency response

20℃ ~30℃,30%~70% relative humidity, 20 dB input attenuation, reference 50 MHz

Preamp off

±0.8 dB;

Preamp on

±0.9 dB;

Accuracy

Input Attenuation Switching Uncertainty

20℃ ~30℃, fc=50 MHz,Preamplifier Off, 20dB RF attenuation,input signal 1~40 dB
±0.5 dB

Absolute Amplitude Uncertainty

20℃ ~30℃, fc=50 MHz,RBW=1 kHz,VBW=1 kHz,peak detector, 20 dB RF attenuation,
Preamplifier Off ±0.4 dB,input signal= -20dBm
Preamplifier On ±0.5 dB, input signal= -40dBm

Uncertainty

input signal range 0dbm~-50dbm

±1.5 dB

VSWR

input 10 dB RF attenuation,1 MHz~1.5GHz

<1.5,nominal

Distortion and spurious response

Second harmonic distortion

fc ≥ 50 MHz,Preamp off, signal input -30 dBm, 0 dB RF attenuation, 20 ℃ to 30 ℃

-65dbc

Third-order intermodulation

fc ≥ 50 MHz

+2 dBm (NSA1015/NSA1032/NSA1036)
+10dBm(NSA1075)

1 dB Gain Compression

fc ≥ 50 MHz, 0 dB RF attenuation,Preamp off , 20 ℃ to 30 ℃

+2 dBm, nominal

Residual response

connect 50 Ω load at input port,0 dB input attenuation,20 ℃ to 30 ℃

<-85dBm,nominated

Input related spurious

-30 dBm signal at input mixer,20 ℃ to 30 ℃

<-60 dBc

Sweep time and triggering

Span range

100Hz≤SPAN≤3GHz 10ms to 3000s
zero sweep width 1ms to 3000s

Mode

Continue, single

Trigger

Free run, video

Tracking generator

Output frequency range

100 kHz~3.2 GHz

Output power level range

-40 dBm~0 dBm

Output power level resolution

1dB

Output flatness

+/-3 dB

Maximum safe reverse level

Average total power:+30 dBm,DC : ±50 VDC

Inputs and Outputs

Front panel RF input connector

50 Ω,N-type female

Front panel track generator output

50 Ω,N-type female

10 M reference input

50 Ω,N-type female

Communication port

USB HOST, USB DEVICE, LAN, earphone port, REF and VGA

General techincal specification

Display

TFT LCD,10.4 inches

Weight (without package)

About 5 kg

Dimension (W × H × D)

421 × 221 × 115 (mm)

Working temperature

0~40 ℃

Storage temperature

-20 °C to +60 °C

Power

100V~240V 50/60Hz

Part list

  • XSA1032(TG) spectrum analyzer
  • Power cord
  • CDROM
  • Quick guide

Support



click for more info
ManufacturerOwon
Manufacturer's modelOwon XSA1032-TG
User manualsonly in English
Measures421 x 221 x 115 mm
Weight5kg
Size10.4 inches
Bandwidth3.2GHz

Accessories

 